Biomechanics Research - Mechanics of Living Organisms, Movement, Locomotion, Prosthetic Limbs

Biomechanics Research Today is a free monthly online journal that collates and summarizes the latest research about Biomechanics, including details on mechanics of living organisms, movement, locomotion, prosthetic limbs.


Biomechanics Research Today

Home

View Latest Issue

Information About Biomechanics

Books on Biomechanics

Advertising in Research Today

View Other Research Today Publications



Old habits tie hard: an in vitro comparison of first-throw tension holding in Polyglycolic acid (Dexon S) and Polyglactin 910 (Coated Vicryl).

Kersey TL, Patel S, Thaller VT

Royal Eye Infirmary, Mutley Plain, Plymouth, UK. thomaskersey@doctors.net.uk

PURPOSE: To compare the first-throw tension holding property of two braided absorbable sutures commonly used in oculoplastic surgery. METHODS: The study was an in vitro experimental model. 6/0 Polyglycolic acid (Dexon S) and 6/0 Polyglactin 910 (Coated Vicryl) were compared using an experimental model to determine first-throw knot security. A polypropylene suture (Surgipro 2) was included as a benchmark to judge the apparatus by, ensuring that our experiment could be designed independently of the test suture materials. Increasing metric loads were applied to the first double throw of a surgical knot. Each suture was tested to the point of knot slipping and the critical tension recorded. All the sutures were kept wet during use. Three variations of the experiment were undertaken: experiment 1 -- two metal loops brought together by the test suture; experiment 2 -- two strips of tissue brought together by the test suture; and experiment 3 -- a knot tied over a metal bar coated in tissue. The tissue used was processed cross-linked porcine dermal collagen (Permacol). Each experiment was repeated three times for each suture type and the mean value taken. RESULTS: Experiment 1: Dexon S 12.2 g (11, 12, 13.5), Coated Vicryl 2.5 g (2.5, 2.5, 2.5) and Surgipro 2 2.3 g (2, 2, 3); experiment 2: Dexon S 33.33 g (30, 35, 35), Coated Vicryl 25 g (25, 25, 25) and Surgipro 2 5 g (5, 5, 5); experiment 3: Dexon S 100 g (100, 100, 100), Coated Vicryl 56.667 g (60, 55, 55) and Surgipro 2 5 g (5, 5, 5). CONCLUSIONS: Dexon S-braided absorbable suture has significantly better first-throw knot security when compared with Coated Vicryl. This is an important property when suturing tissues under tension as it minimizes slippage before the locking throw is tied.

Published 21 April 2006 in Clin Experiment Ophthalmol, 34(2): 152-5.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Biomechanics Research Today. All Rights Reserved.



Biomechanics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Biomechanics Books

Introduction To Kinesiology

Introduction To Kinesiology