Biomechanics Research - Mechanics of Living Organisms, Movement, Locomotion, Prosthetic Limbs

Biomechanics Research Today is a free monthly online journal that collates and summarizes the latest research about Biomechanics, including details on mechanics of living organisms, movement, locomotion, prosthetic limbs.


Biomechanics Research Today

Home

View Latest Issue

Information About Biomechanics

Books on Biomechanics

Advertising in Research Today

View Other Research Today Publications



Influence of lever arm and stabilization on measures of hip abduction and adduction torque obtained by hand-held dynamometry.

Krause DA, Schlagel SJ, Stember BM, Zoetewey JE, Hollman JH

Physical Therapy Program, Mayo Clinic College of Medicine, Rochester, MN, USA. krause.david@mayo.edu

OBJECTIVE: To examine the reliability of clinical techniques for testing hip abductor and adductor muscle performance. DESIGN: Repeated measures. SETTING: Academic laboratory. PARTICIPANTS: A sample of 21 healthy subjects (12 men, 9 women) between 22 and 31 years of age. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Reliability of repeated measures was estimated by calculating intraclass correlation coefficients. Torque production capability was calculated by multiplying force output obtained with a hand-held dynamometer by the length of the resistance lever arm. RESULTS: The reliability of abduction testing was greatest in the long-lever condition. Adduction test reliability was greatest in the long-lever condition with bench stabilization. The maximal hip abduction torque tested in the long-lever position was significantly greater (t(20)=9.21, P<.001) than that in the short-lever position. The maximal hip adduction torque occurred using a long lever for resistance application and a bench to stabilize the nontest leg (F(1,20)=15.64, P=.001). CONCLUSIONS: Muscle performance testing of hip abductors and adductors with a hand-held dynamometer can be performed with good to excellent intratester and intertester reliability. Hip abduction testing is best performed with a long lever. Hip adduction is best performed with a long lever and a bench to stabilize the nontest extremity.

Published 8 January 2007 in Arch Phys Med Rehabil, 88(1): 37-42.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Biomechanics Research Today. All Rights Reserved.



Biomechanics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Biomechanics Books

Athletic Taping And Bracing

Athletic Taping And Bracing